The 22 Kilonewton Anchor Is Not a Canadian Rule

The 22 Kilonewton Anchor Is Not a Canadian Rule

Ask anyone on a Canadian site what a fall arrest anchor has to hold and you will get the same answer: 22 kilonewtons, roughly 5,000 pounds. It is on toolbox cards, in training decks, and in the heads of most competent workers in the country.

It is also not the rule in most of Canada. Ontario sets 8 kN for a temporary fixed support, and 6 kN if the system includes a shock absorber. Alberta sets 16 kN. Quebec sets 18 kN. The Northwest Territories and Nunavut set 8.75 kN. Prince Edward Island works from 17.8 kN for a lifeline on a static line. The 22 kN figure is real, but it belongs to British Columbia, Nova Scotia and a handful of others, and quoting it nationally means most Canadian supervisors are carrying a number that does not match the regulation they are actually working under.

That matters in both directions, which is the part worth sitting with. A crew applying 22 kN in Ontario is over-specifying, which is harmless. A crew applying Ontario's 8 kN figure in British Columbia is under-specifying by a factor of nearly three, and the anchor is the component with no backup.

Where the 22 kN number came from and why it travels

Twenty-two kilonewtons is approximately 5,000 pounds of force, and it appears in enough places to feel universal. It is the figure in several provincial regulations, it matches long-standing North American practice for non-engineered anchorages, and equipment manufacturers routinely rate hardware to it or above so that one product can be sold across every jurisdiction.

That last point is why the number spreads. A manufacturer stamping 22 kN on an anchor connector is not telling you your legal requirement; it is telling you the product clears the highest common requirement in the market. Reading a product rating as a regulation is the mistake, and it is an easy one, because the rating is printed on the thing in your hand and the regulation is in a document nobody brought to the roof.

The honest version is that there is no Canadian anchor number. There are fifteen sets of them, and the one that governs you is the one in your own jurisdiction's occupational health and safety regulation.

What each jurisdiction actually requires

The Canadian Centre for Occupational Health and Safety maintains a jurisdiction-by-jurisdiction summary of anchor strength legislation, and the spread in it is wider than most people expect.

Jurisdiction Fall arrest anchor requirement
British Columbia 22 kN, or twice the maximum arrest force. Permanent anchors also 22 kN
Alberta 16 kN per worker, or twice the maximum arresting force
Saskatchewan 22.2 kN per worker for lifeline and personal fall arrest anchor points
Manitoba Permanent: 22.2 kN per worker, certified by a professional engineer. Temporary fixed support: 8 kN, or 6 kN with a shock absorber
Ontario Temporary fixed support: 8 kN, or 6 kN where a shock absorber is used. Fall restricting: 6 kN
Quebec Single point: 18 kN, or engineer-designed to twice the maximum arrest force, or certified to EN 795 or CSA Z259.15
New Brunswick 22 kN, or four times the maximum load when used under a competent person's direction
Nova Scotia Non-engineered: 22 kN. Engineered: twice the anticipated maximum arresting force
Prince Edward Island Lifeline on a static line: the greater of the maximum likely load or 17.8 kN
Newfoundland and Labrador The greater of the maximum likely load or 22.2 kN
Northwest Territories and Nunavut 8.75 kN per worker for personal fall arrest anchors installed one year or more after the provision took effect
Yukon Natural anchors such as trees or rock: 22 kN ultimate capacity, plus a second anchor of equal capacity
Federal No kilonewton figure in the regulation; refers to the CSA Z259 standards

Two things jump out of that table. The first is that the federal jurisdiction, which covers interprovincial trucking, rail, telecommunications, banking and port operations, does not state a number at all. It points to the CSA Group Z259 series, which means a federally regulated employer has to read the standard rather than the regulation to know what to install.

The second is Ontario and Manitoba's shock absorber provision, which is the most practically useful detail on the page and the one almost nobody knows.

The shock absorber changes the anchor requirement

In Ontario and Manitoba, a temporary fixed support has to hold 8 kN, but only 6 kN where the system includes a shock absorber. That is not a loophole or a discount. It is the regulation recognizing the physics.

An energy absorber, usually a tear-away pack in the lanyard, extends the deceleration over a longer distance and a longer time. The peak force transmitted to the body and to the anchor drops substantially as a result. A rigid lanyard clipped to a rigid anchor stops a falling worker almost instantly, and the forces involved can injure the person badly even when every component holds. The absorber exists primarily to protect the worker's body, and the lower anchor figure is a downstream consequence.

Several jurisdictions express the same idea differently, as a multiple rather than a fixed number: twice the maximum arrest force in British Columbia, Alberta and Nova Scotia's engineered case, four times the maximum load in New Brunswick under a competent person's direction. Those formulations are better engineering, because they tie the anchor to the actual system rather than to a round number, and they require you to know what your system's maximum arrest force is. If nobody on the crew can state that figure for the lanyard in use, the multiple cannot be applied.

Travel restraint is a different system with a different number

The anchor figures above are for fall arrest, meaning the worker can fall and the system stops them. Travel restraint is the system that stops the worker from reaching the edge at all, and its anchor requirements are an order of magnitude lower: 2 kN in Ontario, 3.5 kN per worker in Alberta, Saskatchewan, the Northwest Territories and Nunavut, and 3.5 kN or four times the worker's weight in British Columbia.

The logic is simple. A restraint anchor never takes a fall load, because a correctly set up restraint system means a fall cannot occur. It only ever holds a person leaning on it.

Which is exactly why the distinction gets dangerous. A restraint anchor is cheap, light and easy to install, and it looks identical to the worker clipping on. If the lanyard length is wrong, if the worker moves to a different part of the roof, or if the anchor was positioned for a different work area, a restraint system silently becomes a fall arrest system attached to an anchor rated for a fraction of the load. The system has to be set up so the worker physically cannot reach a position from which they could fall, and that has to be re-checked whenever the work moves.

Manitoba's numbers show the same gradient within fall arrest itself: 8 kN for a temporary fixed support without a shock absorber, 6 kN with one, and 2 kN for travel restraint. Three different anchors on the same roof, three different requirements.

FOOTWEAR FOR SLOPED AND ELEVATED WORK

Grip and ankle support matter more the further you are from the ground. Workman Industrial stocks CSA-certified safety footwear, and our guides to boots for roofers and ironworkers cover what to look for.

A rated anchor does not mean a safe system

Here is the failure that kills people who did everything they were told. The harness fits, the anchor is rated, the lanyard is certified, the worker clips on correctly, falls, and hits the ground anyway.

The reason is clearance. A fall arrest system needs vertical space below the worker to work, and the required distance is the sum of several things: the free fall distance before the system engages, the deceleration distance as the shock absorber deploys, the stretch in the lanyard and harness, the height of the worker below their own attachment point, and a safety margin. For a typical shock-absorbing lanyard the total runs to several metres.

Which produces a result that sounds wrong and is correct: on a low elevation there may not be enough room below for a shock-absorbing lanyard to function. In that situation the answer is a different system, usually a self-retracting device that engages almost immediately, or travel restraint, or a guardrail. It is not "clip on anyway because something is better than nothing."

Two related points. An anchor placed below the worker's attachment point increases free fall distance, so overhead anchors are strongly preferred. And a horizontal lifeline sags under load, which adds to the fall distance and increases the force on the end anchors dramatically; this is why jurisdictions regulate them separately, with New Brunswick requiring 89 kN wire rope breaking strength and 71 kN end anchors for a non-engineered horizontal lifeline, and Quebec requiring 90 kN end anchors with a 12 metre maximum span and a limit of two workers at a time on a construction site.

Engineered, non-engineered, and who signs

Several jurisdictions split the requirement by whether an engineer was involved. Nova Scotia is the clearest: 22 kN for a non-engineered anchorage, or twice the anticipated maximum arresting force where the anchorage is engineered. Manitoba requires permanent anchors to be certified by a professional engineer. Quebec accepts an engineer-designed anchor at twice the maximum arrest force as an alternative to its 18 kN figure, or certification to EN 795 or CSA Z259.15. Alberta exempts anchors installed before 1 July 2009 from its permanent requirement, which is a detail worth knowing on any older building.

The practical reading is that an engineer can design to a lower absolute number because they have calculated the actual loads, while the fixed figures exist precisely for situations where nobody has done that calculation. Choosing the engineered route means producing the documentation; it does not mean asserting that an engineer would probably have been fine with it.

This is also where anchor identification matters. A permanent roof anchor should be labelled with its rating and its last inspection, and on a building where anchors were installed by a previous owner or contractor, an unlabelled fixture is not an anchor. It is a piece of metal. Treating it as rated because it looks like the ones on the last job is the kind of assumption that the due diligence standard does not forgive.

After the fall, the clock starts

A fall arrest system that works leaves a conscious or unconscious worker hanging in a harness, and that is an emergency with a short timeline rather than a resolved incident. Suspension in a harness restricts blood return from the legs and can become life-threatening well inside the time it takes for an unplanned rescue to be organized, which is covered in detail in our article on suspension trauma and post-fall rescue.

The same structural point applies here as in confined space entry: the rescue plan has to exist before the work starts, has to be specific to that location, and cannot consist of assuming the fire department will arrive in time. A fall protection plan that stops at the anchor rating is half a plan.

Any component that has arrested a fall comes out of service permanently. Shock absorbers have deployed, webbing has taken a shock load that is not visible, and anchors may have yielded. The hardware does not get a second use, and the incident gets the investigation and reporting treatment on the normal statutory timelines.

What to check before clipping on

Know your own number

Look up the anchor requirement in your own jurisdiction's regulation rather than working from a training deck, a manufacturer's stamp, or this article. If your jurisdiction expresses it as a multiple of maximum arrest force, find out what that force is for the specific lanyard in use.

Confirm which system you are actually using

Fall arrest, fall restricting, and travel restraint carry different anchor requirements and different equipment. Decide deliberately, and re-check when the work area moves, because a restraint system that no longer restrains is a fall arrest system on an underrated anchor.

Do the clearance arithmetic

Add free fall, deceleration, harness and lanyard stretch, worker height below the attachment, and a margin. If the available clearance is less than that total, change the system rather than the hope. Prefer overhead anchorage, and account for horizontal lifeline sag separately.

Inspect and identify

Check webbing, stitching, hardware and labels before each use, and treat unlabelled fixtures as unrated. Permanent anchors need documented inspection, which belongs in the regular site inspection program rather than in somebody's memory.

Check who is allowed up there

Fall protection work is a poor fit for workers who have been on site a few days, which is one of the practical consequences of the points in our articles on new and young worker orientation and on why paying an agency premium does not transfer the duty. On multi-employer sites, settle in writing who owns the anchors, the inspection records and the rescue capability, because prime contractor obligations do not resolve that automatically. And nobody should be working at height alone where a fall would go unnoticed, as covered in our piece on working alone and isolated worker safety.

Consider whether you need a harness at all

The hierarchy still applies. A guardrail protects everyone who walks near the edge without requiring anyone to clip onto anything, and it does not fail because somebody was in a hurry. Personal fall arrest is near the bottom of the hierarchy for a reason. Where the work is on scaffold, from a ladder, in a scissor or boom lift, or around an open excavation, the equipment-specific rules come first and the anchor question may not arise at all.

Frequently asked questions

What anchor strength is required for fall arrest in Canada?

It depends on the jurisdiction. British Columbia and Nova Scotia use 22 kN, Saskatchewan and Newfoundland and Labrador 22.2 kN, Alberta 16 kN, Quebec 18 kN, Prince Edward Island 17.8 kN for a lifeline on a static line, the Northwest Territories and Nunavut 8.75 kN, and Ontario 8 kN for a temporary fixed support. Several jurisdictions allow a multiple of maximum arrest force instead. The federal regulation states no figure and refers to the CSA Z259 standards.

Is 22 kN the fall protection anchor requirement in Canada?

No. It is the requirement in some jurisdictions and a common equipment rating, which is why it is widely assumed to be national. Ontario, Alberta, Quebec, Prince Edward Island, the Northwest Territories and Nunavut all set lower figures. Working to 22 kN where a lower figure applies is harmless, but applying a lower figure where 22 kN is required leaves the anchor substantially underrated.

What anchor strength is needed for travel restraint?

Much less, because a restraint anchor never takes a fall load. Ontario sets 2 kN, Alberta, Saskatchewan, the Northwest Territories and Nunavut set 3.5 kN per worker, and British Columbia sets 3.5 kN or four times the worker's weight. This only holds if the system genuinely prevents the worker from reaching a position where a fall is possible, which has to be re-verified whenever the work area changes.

Does a shock absorbing lanyard reduce the anchor strength required?

In some jurisdictions, yes. Ontario and Manitoba reduce the temporary fixed support requirement from 8 kN to 6 kN where a shock absorber is used, because the absorber extends the deceleration and lowers the peak force reaching the anchor. Jurisdictions that express the requirement as a multiple of maximum arrest force achieve the same effect arithmetically. The absorber's main purpose is still to protect the worker's body.

Do fall protection anchors need to be certified by an engineer?

Sometimes. Manitoba requires permanent anchors to be certified by a professional engineer. Nova Scotia permits a lower engineered value as an alternative to its 22 kN non-engineered figure, and Quebec accepts an engineer-designed anchor or certification to EN 795 or CSA Z259.15. Where the engineered route is used, the documentation has to exist. Alberta exempts anchors installed before 1 July 2009 from its permanent requirement.

At what height is fall protection required in Canada?

There is no single national height. Thresholds differ by jurisdiction and by sector, and many jurisdictions also require protection regardless of height where a fall would be into water, into operating machinery, or into a substance a worker could drown in or be engulfed by. Because the figures vary and are amended periodically, confirm the current trigger with your own regulator rather than relying on a remembered number.

The anchor is the component with no backup

Everything else in a fall arrest system has some tolerance. Webbing is overbuilt, hardware is tested, absorbers are forgiving. The anchor is the single point where the whole load arrives, and it is the component most often chosen by whoever was nearest to it with the least information.

Which is why the number is worth getting right rather than remembering. Look it up for your own jurisdiction, write it on the plan, and treat a product stamp as a product stamp. The CCOHS summaries of Canadian fall protection legislation are the fastest way to see where your jurisdiction sits before you go to the regulation itself.

Workman Industrial does not sell harnesses, lanyards, self-retracting devices or anchor hardware, and we would not specify a fall protection system for your building. That equipment belongs with fall protection specialists and, where the regulation says so, with an engineer. What we supply is the footwear and workwear the crew is wearing while they do the work properly.

KITTING OUT A CREW THAT WORKS AT HEIGHT

Certified footwear, hi-vis apparel for anyone working below the drop zone, and the CSA work boot guide if you are specifying footwear for the first time. If you are also handling loads at height, our article on rigging and sling angles covers the other place Canadian load ratings get misread.

Back to blog

Leave a comment

Please note, comments need to be approved before they are published.